Bag Filters
, Fancoil Filters ,
Fine
Filters, Air
Cleanable Type Pre Filters, Laminar
Air Flow Pre Filters, Water
Washable Type Pre Filters, Metallic
Viscous Pre Filters, HEPA
Filters , Mini-Pleat
HEPA Fiters, ULPA
Filters
DOP Testing ,
Particle Count Testing , Air
Flow Pattern Visualization Testing
Cleanroom
Projects , Air Curtains
, Air Showers
, Biological
Safety Cabinets Class - I ,
Class - II ,
Class - II Type A/B ,
Class - II Type B1 ,
Class - II Type B2 ,
Class - II Type B3 , Class - III ,
Cleanroom Garment Storage Cabinets , Horizontal
Laminar Air Flow ,
Vertical Laminar Air Flow ,
Powder Dispensing / Sampling Booths , Positive
Pressure Modules ,
Soft wall Cleanrooms , Static
Pass Box ,
Dynamic Pass Box
Class-III Biological Safety Cabinets / Bio Safety
Cabinets
Bio safety cabinets are available in Stainless steel and GI with
PU coated construction. Worktables are of removable type and suitable
for oven baking. Inner surface are completely line with stainless
steel. HEPA filters are of Minipleat type. Differential pressure
is monitored through specially designed low-pressure gauges. Working
chamber is provided with UV & Illumination tubes. Feather-touch
control switch with indicators are provided for the operations of
Blower / Illumination / UV - Ultra Violet Lamp
Biological safety cabinets are available with various optional Special
features such as VFD controlled air-blowers for adjustable airflow,
Operation of UV - Ultra Violet Lamp integrated with the front-door
movement to avoid accidental exposure to UV - Ultra Violet rays,
warning alarm when differential pressure exceeds the limit to indicate
filter choking level, warning alarm when the front sash is opened
beyond safety-level
Biohazard safety cabinets are available in various standard sizes
and custom-built sizes to suit user's requirement
Bio Hazard Safety Cabinet - Class III
Recommended for Personnel and Environment protection
These cabinets are totally enclosed ventilated unit of airtight
construction. Operations in the cabinet are conducted through glove-ports,
which are provided with rubber gloves. The Cabinet unit is maintained
under negative pressure. Supply air is drawn into the cabinet through
HEPA filters. The exhaust air is treated by HEPA filtration and
incinerations. This type of cabinet systems provides the means to
control air borne particulates containments including micro - organisms
determined to be potentially harmful to personnel the product and
the environment. These cabinets provides high level of protection
to the personnel and the environment
| Cleanliness |
Class 5 air cleanliness as per ISO 14644-1 ,
Class 100 air cleanliness as per US Federal Standard 209E |
| Air Balancing |
0% re-circulation & 100% exhaust |
| Particle retention |
0.3 Micron & above |
Note - Optionally ULPA filters can also be fitted to
acheive ISO Class 3 air cleanliness within workzone as per ISO 14644-1
(Equivalent to Class 1 air cleanliness as per US Federal Standard
209E, 100 times better than the usual class 100 air cleanliness
classification)
|
|