Bag Filters
, Fancoil Filters ,
Fine
Filters, Air
Cleanable Type Pre Filters, Laminar
Air Flow Pre Filters, Water
Washable Type Pre Filters, Metallic
Viscous Pre Filters, HEPA
Filters , Mini-Pleat
HEPA Fiters, ULPA
Filters
DOP Testing ,
Particle Count Testing , Air
Flow Pattern Visualization Testing
Cleanroom
Projects , Air Curtains
, Air Showers
, Biological
Safety Cabinets Class - I ,
Class - II , Class - II Type A/B ,
Class - II Type B1 ,
Class - II Type B2 ,
Class - II Type B3 ,
Class - III ,
Cleanroom Garment Storage Cabinets , Horizontal
Laminar Air Flow ,
Vertical Laminar Air Flow ,
Powder Dispensing / Sampling Booths , Positive
Pressure Modules ,
Soft wall Cleanrooms , Static
Pass Box ,
Dynamic Pass Box
Class-II Type A/B Biological Safety Cabinets / Bio Hazard Safety
Cabinets
Bio safety cabinets are available in Stainless steel
and GI with PU coated construction. Worktables are of removable
type and suitable for oven baking. Inner surface are completely
line with stainless steel. HEPA filters are of Minipleat type.
Differential pressure is monitored through specially designed low-pressure
gauges. Working chamber is provided with UV & Illumination tubes.
Feather-touch control switch with indicators are provided for the
operations of Blower / Illumination / UV - Ultra Violet Lamp
Biosafety cabinets are available with various optional Special features
such as VFD controlled air-blowers for adjustable airflow, Operation
of UV - Ultra Violet Lamp integrated with the front-door movement to avoid accidental
exposure to UV - Ultra Violet rays, warning alarm when differential pressure exceeds
the limit to indicate filter choking level, warning alarm when the
front sash is opened beyond safety-level
Biosafety cabinets are available in various standard sizes and custom-built
sizes to suit user's requirement
Biosafety Cabinet Class II - Type A/B
Recommended for Product & Personnel protection
Class II Type A/B Bio safety cabinets differs in the proportion
of air exhausted and re-circulated within the cabinet; velocity
of airflow to the work zone creates an ultra-clean environment for
product protection. An air barrier between the operator and the
work zone is maintained by a flow of room air into a full width
grille in the work opening. The barrier air mixes with the laminar
air in a sump underneath the work surface, and is re-circulated
with in the cabinet through HEPA filter.
Class II Type A/B Biohazard Safety Cabinets are not recommended
for use with gases or vapors. A primary application is for sterile
packaging. Care is required while decontaminating the cabinet.
| Air Cleanliness |
Class 5 air cleanliness as per ISO 14644-1 ,
Class 100 air cleanliness as per US Federal Standard 209E |
| Air Balancing |
70% re-circulation & 30% exhaust |
| Particle retention |
0.3 Micron and above |
Note - Optionally ULPA filters can also be fitted to
acheive ISO Class 3 air cleanliness within workzone as per ISO 14644-1
(Equivalent to Class 1 air cleanliness as per US Federal Standard
209E, 100 times better than the usual class 100 air cleanliness
classification)
|
|