Spectroscopy - Double Beam Atomic Absorption Spectrophotometer
Technical Features
|
|
High energy double beam optics. |
| Automated six-lamp turret with independent
power supply and alignment for each lamp. |
| Microprocessor based, User friendly,
Menu driven, with Printer interface and optional PC attachment
through RS 232C interface. |
| MS Windows based software for Data Processing,
Storage, Retrieval, Interpretation etc. |
| Modes of operation include Absorbance,
Concentration, Standard addition & Emission. |
| Background correction with D2 lamp source. |
| Precise vertical, lateral and rotational
alignment of Titanium burner. |
| Saving of optimal parameters |
| Self-Diagnostics. |
Applications
For analysis in various metallic constituents in Soil, Fertilizers,
Micro Nutrients, Plants, Pesticides, Foods, Water, Biological Matter,
Metallurgy, Plating, Coal, Petrochemicals, Glass, Cement, Steel
and other Industries.
| Specifications |
|
SPECTRAL
|
| Range : |
185 to 930nm |
| Accuracy : |
0.5nm |
| Bandwidth :
|
Automated setting in eight
steps - 0.125, 0.25, 0.5, 0.75, 1.0, 1.5, 2 & 2.5nm. |
|
|
|
PHOTOMETRIC
|
| Range : |
0 to 2Abs |
| Accuracy : |
0.01Abs at 1.0Abs |
| Integration
Time : |
0.04 to 99sec |
| LIGHT SOURCE
: |
Hallow Cathode Lamp
(HCL) |
| BACKGROUND CORRECTION
: |
Deuterium Lamp (D2) |
| BURNER : |
Titanium construction,
Premix, Laminar flow, 100mm |
| FUEL : |
Acetylene (C2H2) |
| OXIDANT : |
Air/Nitrous Oxide (N2O) |
| FLOW CONTROL
: |
Integral Gas Control System
with panel flow meters |
| NEBULIZER : |
Pneumatic, with 90% Platinum
& 10% Iridium alloy capillary |
| Sample feed
rate : |
3 to 8mL/min (Adjustable) |
| MONOCHROMATOR
: |
Czerny-Turner 1/3 meter
with 1200lines/mm holographic diffraction grating and hard
coated optics |
| DETECTOR : |
Wide range photo multiplier
tube (PMT) |
| READOUT : |
2 line 24 character dot
matrix backlit LCD module |
|
|
|
POWER SUPPLY
|
| HC Lamp : |
0 to 30mA, modulated |
| D2 Lamp : |
15 to 300mA, modulated |
| PMT : |
-200 to -1000V |
| POWER REQUIREMENT
: |
230 V 10%, 50Hz,
1 , Max 200VA |
|
|
|
PHYSICAL DIMENSIONS
|
| Size (WxDxH)
in mm : |
860 x 530 x 360 |
| Weight in kg
: |
Approx. 50 |
Accessories Supplied
With instrument : 100mm Burner
(Air - C2H2), Nebulizer with SS Capillary
At extra cost : HC lamps of desired elements,
Background correction with D2 lamp, 50mm Burner for N2O - C2H2,
Nebulizer with Pl-Ir capillary, Hydride/Vapour Generator, Compressor,
Printer, PC & Software
Optional