                Stable, Direct Readout of Absorbance | 
               
               
                | Compact & Easy to operate | 
               
               
                | Rugged, Sturdy & Reliable | 
               
               
                | Thumb Wheel Selection of Filters | 
               
               
                | Pre-focussed Light Source | 
               
               
                | Long Life Photo Diode Detector | 
               
               
                | Only 1 ml of Sample need | 
               
               
                | Usable for Disposable cells | 
               
               
             
            
            Colorimeter 
              Application In determination of concentration of constituents in 
              - Clinical, Pharmaceutical, Food, Beverage & Water Analysis 
              - Analytical & Agricultural Chemistry 
              - Metallurgy 
             
             
              Colorimeter Operation Principle
            When light, of comparatively narrow range of wavelengths in the 
              visible spectrum,is passed through a homogeneous medium, a part 
              of the light is reflected, a part is absorbed within the medium 
              and remainder is transmitted. The intensity of the light emerging 
              from the medium decreases exponentially as the concentration and 
              thickness of the absorbing medium increase arithmetically, as per 
              laws of Beer & Lambert. If the container and the thickness of 
              the medium is kept constant, the intensity of light emerging out 
              of the medium, with respect to the incident light, is directly proportional 
              to the concentration of the medium. 
               
              With this principle, in colorimetry, the concentration of a coloured 
              solution is determined by measurement of relative absorption of 
              light with respect to a solution of known concentration  
            This COLORIMETER CL 157 is a table top, ergonomically engineered 
              instrument with its components and modules inside and controls, 
              readouts, etc., on the panels outside laid out for ease of operation 
              and maintainability 
               
              Light from pre-focussed tungsten filament lamp is focussed by a 
              lens system on to a photocell through filters, of discrete bands 
              of overlapping wavelengths covering the visible spectrum, selectable 
              by a filter wheel, and a test tube/cell containing solution under 
              investigation. The electrical output of a photo diode is processed 
              and the value of absorbance displayed on the readout 
               
              The instrument is incorporated with facilities to adjust the intensity 
              of light, appropriate for the expected concentration of the sample, 
              by aperture control and prevention of exposure of photocell to the 
              light, when measurement is not being carried out, by use of a shutter. 
               
             
            
               
               
                | Photometric | 
               
               
                | Range | 
                -0.1 to 1.99 Abs | 
               
               
                | Repeatability | 
                ± 0.01 Abs | 
               
               
                | Stability | 
                ± 0.01 Abs in 8 h | 
               
               
                ![]()  | 
               
               
                | Light Source | 
                Tungsten Lamp | 
               
               
                ![]()  | 
               
               
                | Filters (8) | 
                Peak Transmission at 450, 470, 490, 520, 540, 570, 600 & 
                  670 nm | 
               
               
                ![]()  | 
               
               
                | Shutter | 
                To prevent the detector from continuous exposure to light | 
               
               
                ![]()  | 
               
               
                |   | 
                Photo diode | 
               
               
                ![]()  | 
               
               
                | Readout | 
                2½ Digit 7 segment LED display of 12.7mm height | 
               
               
                ![]()  | 
               
               
                | Power Requirement | 
                230 V ± 10%, 50 Hz, 1   , Max. 20VA | 
               
               
                ![]()  | 
               
               
                | Physical Dimensions | 
               
               
                | Size (WxDxH) in mm | 
                270 x 180 x 110 | 
               
               
                | Weight in Kg. | 
                Approx. 3.0 | 
               
               
                ![]()  | 
               
               
                | Accessories Supplied | 
               
               
                | With Instrument | 
                Matched 3 mL test tubes, holder for 10mm path length glass 
                  cuvettes disposable cells | 
               
               
                | At Extra cost | 
                Glass cuvettes & disposable cells | 
               
               
                | 
                   Specifications subject to change due to continuous 