|  Download Full Catalog 
 Product Description :
 
 
                            Available in four scale ranges, the   Elcometer 155 is designed to measure uncured powder coating film   thickness. This enables the application system to be set up and fine   tuned prior to the curing process. In turn, this will reduce the amount   of scrap and over-spray.
 Place the comb into the powder and slide   the comb along the surface. The measurement points (or teeth) are   pointed and allow the powder to flow around them.
 The thickness of the powder lies between the highest value where a   drag mark is visible and the lowest value where a drag mark has not been   produced.
 Note: The thickness of a coating prior to cure is not   the same value after curing but there is a correlation. The powder comb   is suitable as a guide only.
 
 The Elcometer 155 is not available for sale in the USA.
                             Technical Specification :
 
 
                            
                              
                                | Part Number | Description | Range |  
                                | B15513573-5 | Elcometer 155 Metric Powder Film Comb | 50 - 255µm |  
                                | B15513573-6 | Elcometer 155 Metric Powder Film Comb | 225 - 1250µm |  
                                | B15513573-1 | Elcometer 155 Imperial Powder Film Comb | 2 - 9 mils |  
                                | B15513573-2 | Elcometer 155 Imperial Powder Film Comb | 9 - 50mils |  
                                | B15513573-10 | Metric Comb Set (2 combs) | 50 - 225µm and 225 - 1250µm |  
                                | B15513573-9 | Imperial Comb Set (2 combs) | 2 - 9mils and 9 - 50mils |  
                                | Accuracy | ±5µm (±0.2mil) |  
                                | Dimensions | 38mm x 46mm (1.5” x 1.8”) |  
                                | Weight | 18g (0.6oz) |  
                                | Certificate available | Certificate of Calibration: issued for Fixed Calibration equipment and shows readings and traceability. Accredited Certificate: can be issued for Fixed Calibration Equipment   and a full UKAS traceable certificate is issued from an independent   Calibration Laboratory.
 |  
                                | Packing List | Elcometer 155 Powder Comb and powder comb wallet for two combs |  Can be used in accordance with:
 ASTM D7378-A
 
  Download Full Catalog
 |