MultiLab India Logo
Multilab Contact
HOME spilt ABOUT US spilt PRODUCTS spilt EXPORTS spilt FAQ spilt CONTACT US
Multilab Site Search Loading
 

Elcometer 6910/3 Setaflash Series 3 Active-Cool

elcometer 6910

elcometer 6910 active cool Download Full Catalog

Product Description:


Flash Point is defined as  “the lowest temperature of a liquid at which its vapours will form a combustible mixture with air”.   It is a convenient and reliable classification of the “flammability” of many substances.
  • Open Cup tests simulate an un-contained condition, for example a spillage.
  • Closed Cup tests simulate an enclosed environment, for example storage in a tank or sealed container and are usually specified due to improved precision.
  • Measuring Flash Point

Most industries need to test the Flash Point of raw materials, products or waste to ensure:

Product quality - as a measure of consistency and performance comparison
Compliance testing - to test safety classification for handling, storage, transport and waste
In-service analysis - tests on in-use oils and other substances for contamination / adulteration
General safety - to evaluate hazard potential
Specifications - to check conformance

The Setaflash Series 3 Active-Cool Tester offers the same features as the Elcometer 6910/1 Setaflash but is fitted with a cup suitable for testing corrosive samples.

It has been designed to carry out Flash/No Flash tests rapidly and efficiently to determine the Flash Point of liquids and semi-solids in the 10°C to 130°C (50°F to 266°F) temperature range.

Flash Point is automatically detected using a thermally activated detector,reducing the risk of operator error and minimising the potential danger of inhaling fumes during a test. A rechargeable gas tank with On/Off switch and fine adjustment are integral to the unit. Supplied with a 2ml (0.067fl oz) syringe and ignitor.

Features:

  • Flash Point test in less than 2 minutes
  • Small sample size - 2ml (0.067 fl oz) or 4ml (0.135 fl oz)
  • Electronic Peltier cooling effect
  • °C or °F displa

Technical Specification:

Part Number
Description
UK 240V EUR 220V US 110V
K0UK6910M013 K0006910M013 K0US6910M013 Elcometer 6910/3 Setaflash Series 3 Active-Cool
Sample Size and
Temperature Range
2ml (0.067fl oz) for Flash Points up to 100°C (212°F)
4ml (0.135fl oz) for Flash Points between 100°C to 300°C (212°F to 572°F)
Test Time 1 to 99 minutes
Default Values 1 minute for flash points up to 100°C (212°F)
2 minutes for flash points between 100°C to 300°C (212°F to 572°F)
Cup Material Corrosion resistant steel
Dimensions 256 x 280 x 256mm (10.1 x 11.0 x 10.8”)
Weight 5kg (11.3lb)
Certificate available Certificate of Calibration: issued for Fixed Calibration equipment and shows readings and traceability.
Packing List Elcometer 6910 Setaflash Series 3 active-cool closed cup tester, 2ml (0.067fl oz) syringe, gas canister and ignitor, silicone rubber tubing for gas canister to gas jet connection, silicone sample well ‘O’ ring seal for cup/lid (red coloured), viton sample well ‘O’ ring seal for cup/lid (black coloured), mains power cable, automatic flash detector probe, Series 3 manuals (on CD) and operating instructions


Can be used in accordance with:
ASTMD 1655, ASTMD 3278, ASTMD 3828, ASTMD 3934,  ASTME 502, BS 3900-A11, BS3900-A13
BS 3900- A14, BS 6664-4, BS 6664-4, EN 456, ISO 3679, ISO 3680